Your storage tanks are critical infrastructure. When corrosion, wear, or damage threatens their integrity, you need a partner with the expertise to assess the situation and execute repairs that meet the highest industry standards.
Tate Metalworks brings more than 50 years of experience to API 653 tank repair projects across the United States. Our in-house Professional Engineers and experienced craftsmen help facility owners maintain compliance, extend asset life, and avoid costly unplanned replacements.

What is API 653?
API 653 is the American Petroleum Institute standard that governs the inspection, repair, alteration, and reconstruction of aboveground storage tanks that have already been placed into service. While API 650 covers the design and construction of new welded steel tanks, API 653 addresses what happens after a tank enters operation.
The standard provides requirements for:
- Inspection intervals and methods — determining when and how tanks should be evaluated
- Fitness-for-service assessments — evaluating whether a tank can continue operating safely
- Repair procedures — approved methods for addressing corrosion, cracks, and structural issues
- Alteration guidelines — requirements for modifying existing tanks
- Reconstruction criteria — standards for relocating or rebuilding tanks
For facility owners, API 653 compliance is often mandatory. Regulatory agencies, insurance carriers, and corporate risk management programs frequently require that tank maintenance activities follow this standard. Working with an experienced API 653 contractor ensures your repairs meet these requirements and protect your operation.
Tate Metalworks provides comprehensive storage tank repair services for aboveground tanks of all sizes. Our team handles everything from routine maintenance repairs to complex reconstruction projects.
Effective repairs start with thorough inspection, which help inform repair recommendations. Our inspection services include:
The tank shell and roof are constantly exposed to environmental conditions and internal product contact. Common shell and roof repairs include:
Tank floors often experience the most aggressive corrosion due to product settling and soil-side moisture. Our floor repair capabilities include:
Operational needs change over time. API 653 governs alterations to existing tanks, including:
When tanks need to be relocated or extensively rebuilt, API 653 reconstruction requirements apply. Tate Metalworks has the field erection expertise to execute these complex projects:
One of the most important decisions facility owners face is whether to repair an aging tank or replace it entirely. The right answer depends on several factors, and Tate Metalworks can help you evaluate your options.
Industrial tank repair is often the most cost-effective choice when:
Replacement may be the better long-term investment when:
Tate Metalworks approaches every project as advisors first. Our engineers review inspection data, assess repair scope, and provide honest recommendations based on your specific situation. Sometimes repair is clearly the right choice. Sometimes replacement makes more sense. We help you understand the trade-offs so you can make an informed decision.

Tate Metalworks provides API 653 tank repair services to facilities across a wide range of industries. Our experience with diverse products, operating conditions, and regulatory environments means we understand the unique requirements of your operation.
Oil and Gas — Crude oil storage, refined product terminals, pipeline tank farms, and production facilities rely on our expertise to maintain critical storage assets.
Chemical Processing — Chemical manufacturers and distributors trust us to repair tanks storing corrosive, reactive, and hazardous materials with appropriate safety protocols.
Water and Wastewater Treatment — Municipalities and industrial water users depend on our capabilities for potable water storage, process water tanks, and wastewater treatment vessels.
Power Generation — Power plants require reliable fuel storage and water treatment tanks. We support both conventional and renewable energy facilities.
Food and Beverage — Food-grade storage demands attention to sanitary requirements and product purity. Our teams understand these specialized needs.
Pulp and Paper — The pulp and paper industry's chemical storage and process tanks present unique corrosion challenges that our experience addresses.
Tate Metalworks follows a structured process that ensures quality results, clear communication, and on-time project delivery.
Every project begins with a conversation. We learn about your tank, its history, current concerns, and operational constraints. This helps us understand the scope and develop an appropriate approach.
If inspection data is not already available, our team conducts a thorough evaluation of your tank's condition. We document findings, identify areas of concern, and perform engineering analysis to determine fitness for continued service.
Our in-house Professional Engineers develop a detailed repair plan that addresses identified issues while meeting API 653 requirements. The plan includes repair procedures, material specifications, welding requirements, and quality control measures.
Our experienced craftsmen execute repairs according to the engineering plan. Rigorous quality assurance—including weld inspection, dimensional verification, and testing—confirms that work meets specifications.
Upon completion, we provide comprehensive documentation of all work performed. This includes inspection reports, repair records, material certifications, NDE results, and other documentation required for regulatory compliance and your records.
API 650 is the standard for designing and constructing new welded steel aboveground storage tanks. API 653 governs the inspection, repair, alteration, and reconstruction of tanks that are already in service. Think of API 650 as the "birth certificate" standard and API 653 as the "healthcare" standard for your tank's operational life.
API 653 establishes inspection intervals based on corrosion rates and risk factors. External inspections are typically required at least every five years. Internal inspections may be required every 10 years, though risk-based inspection programs can adjust these intervals based on documented conditions and operating history.
It depends on the extent and location of corrosion. API 653 provides criteria for evaluating minimum acceptable thickness and repair options. In many cases, even significantly corroded tanks can be repaired cost-effectively. Our engineers assess each situation individually and provide honest recommendations.
Project duration varies widely based on scope. Minor repairs may be completed in days. Extensive floor replacements or major shell repairs may require several weeks. During our initial assessment, we provide realistic schedule estimates based on your specific project requirements.
Yes. We offer comprehensive inspection services including visual examination, ultrasonic thickness testing, floor scanning, and fitness-for-service evaluations. Many clients find value in having the same contractor perform both inspection and repairs for continuity and efficiency.
You receive a complete documentation package including inspection reports, repair procedures, material test reports, welder qualifications, NDE results, and as-built drawings as applicable. This documentation supports regulatory compliance, insurance requirements, and your internal asset management records.

Extend the Life of Your Storage Tanks
Ready to Extend the Life of Your Storage Tanks?
Your storage tanks represent significant capital investment. With proper inspection and repair, they can provide decades of additional reliable service.
Tate Metalworks combines engineering expertise, skilled craftsmanship, and a commitment to quality that has earned the trust of facility owners for more than 50 years. Whether you need a fitness-for-service evaluation, routine repairs, or a complex reconstruction project, we have the capabilities to deliver.
Request a Proposal or call us directly at 864.576.3540 to speak to a member of our team.
© 2026 Tate Metalworks. All Rights Reserved|
Privacy & Cookies |
Site by ALINE, A Marketing Company